IGEXPa 05

IGEXPa 05

Product ID: P31408

  • Intrinsically safe sensors for zone 0/20
  • With ATEX- and IECEx-certification
  • Amplifier IKMb... is required for operation
  • For use under rough climatic conditions down to -60 °C
  • Connection: 2 m FEP-cable
  • Waterproof up to 30 m (IP 68) and resistant to high-pressure cleaning (IP 69)
  • For use in refrigeration systems and cooling processes and outdoor areas

M18x1 - sn 5 mm flush

Download specification CAD-Daten Request product Contact

More about this product

Productdata

TYPE IGEXPa 05
Product ID P31408
Thread/sleeve M18x1
Operating Distance sn 5, flush
Ex area uf use Zone 0, Zone 1, Zone 20, Zone 21
ATEX Certificate EPS 17 ATEX 1 173 X
IECEx Certificate IECEx EPS 17.0087X
UKEX Certificate EPS 22 UKEX 1 139 X
ATEX marking gas Ex II 1G Ex ia IIC T6...T3 Ga
ATEX Marking dust Ex II 1D Ex ia IIIC T₂₀₀65°C Da
IECEx marking gas Ex ia IIC T6...T3 Ga
IECEx marking dust Ex ia IIIC T₂₀₀65°C Da
Ambient temperature gas zone 0 T6 -60 ... 60 °C
Ambient temperature gas zone 0 T5 -60 ... 60 °C
Ambient temperature gas zone 0 T4 -60 ... 60 °C
Ambient temperature gas zone 0 T3 -60 ... 60 °C
Ambient temperature dust in zone 20 -60 ... 60 °C
Maximum values Ui = 12.6 V / Ii =15.9 mA / Pi = 50 mW / Ci = 66.2 nF / Li = 1.2 mH
Material housing stainless steel AISI 316 Ti, PTFE, PVDF
Protection [EN 60529] IP 68 (3 bar), IP 69
Electrical connection 2 m FEP-cable 2x0.34 mm²
Note with longer cable available on request

Drawings

IGEXPa 05
IGEXPa 05

CAD Model