IGEX20a 02 GSP

IGEX20a 02 GSP

Product ID: P31379

  • Ex area of use: Zone 0 and Zone 20
  • ATEX- / IECEx-certification
  • External amplifier not required as no intrinsically safe supply necessary
  • Explosion protection realized by type of protection "encapsulation"
  • Installation and commissioning in accordance with EN 60079-14

M12x1 - sn 2 mm flush - Output PNP-NO

Download specification CAD-Daten Request product Contact

More about this product

Productdata

TYPE IGEX20a 02 GSP
Product ID P31379
Thread/sleeve M12x1
Operating Distance sn 2, flush
Output switching output
Output function PNP-NO
Supply voltage 24 V DC +/- 10 %
Switching current max. 50 mA
Rated voltage max. 27 V DC
Rated current max. 50 mA
Ex area uf use Zone 0, Zone 1, Zone 20, Zone 21
ATEX Certificate EPS 17 ATEX 1 117 X
IECEx Certificate IECEx EPS 17.0059X
UKEX Certificate EPS 22 UKEX 1 085 X
ATEX marking gas Ex II 1G Ex ma IIC T6...T3 Ga
ATEX Marking dust Ex II 1D Ex ma IIIC T₂₀₀90°C Da
IECEx marking gas Ex ma IIC T6...T3 Ga
IECEx marking dust Ex ma IIIC T₂₀₀90°C Da
Ambient temperature gas zone 0 T6 -20 ... 55 °C
Ambient temperature gas zone 0 T5 -20 ... 55 °C
Ambient temperature gas zone 0 T4 -20 ... 55 °C
Ambient temperature gas zone 0 T3 -20 ... 55 °C
Ambient temperature dust in zone 20 -20 ... 55 °C
Material housing stainless steel AISI 316 Ti, LCP, POM, PSU
Display LED red
Protection [EN 60529] IP 67
Electrical connection 2 m PUR-cable 3x0,34 mm²
Note with longer cable available on request

Drawings

IGEX20a 02 GSP
IGEX20a 02 GSP

CAD Model