IGEX20a 02 GSP
Product ID: P31379
- Ex area of use: Zone 0 and Zone 20
- ATEX- / IECEx-certification
- External amplifier not required as no intrinsically safe supply necessary
- Explosion protection realized by type of protection "encapsulation"
- Installation and commissioning in accordance with EN 60079-14
M12x1 - sn 2 mm flush - Output PNP-NO
Product request
Contact
Distribution
Do you have a question regarding sales processing, such as delivery conditions or delivery time? Click here for assistance.
Your contact person
Phone:
04346 41580
Technical support
Would you like more technical details, application advice, a replacement for a competitor's model, tips on installation or would you like to discuss possible adjustments? Please contact us!
Your contact person
Phone:
04346 41580
More about this product
Productdata
| TYPE | IGEX20a 02 GSP |
|---|---|
| Product ID | P31379 |
| Thread/sleeve | M12x1 |
| Operating Distance sn | 2, flush |
| Output | switching output |
| Output function | PNP-NO |
| Supply voltage | 24 V DC +/- 10 % |
| Switching current max. | 50 mA |
| Rated voltage max. | 27 V DC |
| Rated current max. | 50 mA |
| Ex area uf use | Zone 0, Zone 1, Zone 20, Zone 21 |
| ATEX Certificate | EPS 17 ATEX 1 117 X |
| IECEx Certificate | IECEx EPS 17.0059X |
| UKEX Certificate | EPS 22 UKEX 1 085 X |
| ATEX marking gas | Ex II 1G Ex ma IIC T6...T3 Ga |
| ATEX Marking dust | Ex II 1D Ex ma IIIC T₂₀₀90°C Da |
| IECEx marking gas | Ex ma IIC T6...T3 Ga |
| IECEx marking dust | Ex ma IIIC T₂₀₀90°C Da |
| Ambient temperature gas zone 0 T6 | -20 ... 55 °C |
| Ambient temperature gas zone 0 T5 | -20 ... 55 °C |
| Ambient temperature gas zone 0 T4 | -20 ... 55 °C |
| Ambient temperature gas zone 0 T3 | -20 ... 55 °C |
| Ambient temperature dust in zone 20 | -20 ... 55 °C |
| Material housing | stainless steel AISI 316 Ti, LCP, POM, PSU |
| Display | LED red |
| Protection [EN 60529] | IP 67 |
| Electrical connection | 2 m PUR-cable 3x0,34 mm² |
| Note | with longer cable available on request |