SDN 554/2 GPP
Product ID: P11314
- 7 segment flow rate indication
- 2 x switching output PNP NO / NC
- Working range 2...20 l/min
- Flow and temperature monitoring of water and water-glycol mixtures
| 2…20 l/min - 4x PNP programmable |
Product request
Contact
Distribution
Do you have a question regarding sales processing, such as delivery conditions or delivery time? Click here for assistance.
Your contact person
Phone:
04346 41580
Technical support
Would you like more technical details, application advice, a replacement for a competitor's model, tips on installation or would you like to discuss possible adjustments? Please contact us!
Your contact person
Phone:
04346 41580
More about this product
Productdata
| TYPE | SDN 554/2 GPP |
|---|---|
| Product ID | P11314 |
| Medium | water / glycol (0, 5, ..., 25, 30 %) |
| Detection range water | 2 ... 20 l/min |
| Detection range water/glycol | 2 ... 20 l/min |
| Temperature monitoring | -10 ... 90 °C |
| Inner diameter d | 15 mm |
| Outer Diameter Pipe mm | 15 mm |
| Process connection | tube fittings for steel tubes accord. to ISO 3304 / DIN 2391 |
| Output | switching output |
| Output function | PNP-NO / NC |
| Supply voltage | 24 V DC +/- 10 % |
| Current consumption max. | 100 mA |
| Switching current max. | 200 mA (20 °C) |
| Reverse polarity protection | ✓ |
| Ambient temperature | 0 ... 60 °C |
| Medium temperature | -10 ... 90 °C |
| Reaction time typ. | 1 ... 8 s |
| Programmable functions | switching point, display flow/temperature, hysteresis, switch on delay, four switching points, time on/off delay, glycol percentage, adjustable to reference, averaging, access code, NC/NO |
| Compressive strength | 20 bar |
| Material sensor touched by medium | stainless steel AISI 316 Ti, FPM |
| Material housing | PBT |
| Display | 7-segment / 3 digits |
| Protection [EN 60529] | IP 65 |
| Electrical connection | M12 connector |
| Accessories | mounting plate, adapter SDA G1/2-Ø-18-L068 (Z01176), adapter SDA G1/4-Ø-10-L050 (Z01175) |