SDN 554/2 GPP

SDN 554/2 GPP

Product ID: P11314

  • 7 segment flow rate indication
  • 2 x switching output PNP NO / NC
  • Working range  2...20 l/min
  • Flow and temperature monitoring of water and water-glycol mixtures
2…20 l/min - 4x PNP programmable


Download specification CAD-Daten Request product Contact

More about this product

Productdata

TYPE SDN 554/2 GPP
Product ID P11314
Medium water / glycol (0, 5, ..., 25, 30 %)
Detection range water 2 ... 20 l/min
Detection range water/glycol 2 ... 20 l/min
Temperature monitoring -10 ... 90 °C
Inner diameter d 15 mm
Outer Diameter Pipe mm 15 mm
Process connection tube fittings for steel tubes accord. to ISO 3304 / DIN 2391
Output switching output
Output function PNP-NO / NC
Supply voltage 24 V DC +/- 10 %
Current consumption max. 100 mA
Switching current max. 200 mA (20 °C)
Reverse polarity protection ✓
Ambient temperature 0 ... 60 °C
Medium temperature -10 ... 90 °C
Reaction time typ. 1 ... 8 s
Programmable functions switching point, display flow/temperature, hysteresis, switch on delay, four switching points, time on/off delay, glycol percentage, adjustable to reference, averaging, access code, NC/NO
Compressive strength 20 bar
Material sensor touched by medium stainless steel AISI 316 Ti, FPM
Material housing PBT
Display 7-segment / 3 digits
Protection [EN 60529] IP 65
Electrical connection M12 connector
Accessories mounting plate, adapter SDA G1/2-Ø-18-L068 (Z01176), adapter SDA G1/4-Ø-10-L050 (Z01175)

Drawings

SDN 554/2 GPP
SDN 554/2 GPP

CAD Model