Productdata

TYPE UF2GKa 075 Ex-L120
Product ID P21257
Switching Point -10 mm
Medium liquid media
Process connection G3/4
Sensor length L 120 mm
Ex area uf use Zone 0
ATEX Certificate EPS 18 ATEX 1 097 X
IECEx Certificate IECEx EPS 18.0054X
UKEX Certificate EPS 23 UKEX 1 052 X
ATEX marking gas Ex II 1 G Ex ia IIC T6…T3 Ga
IECEx marking gas Ex ia IIC T6...T3 Ga
Ambient temperature gas zone 0 T6 -25 ... 75 °C
Ambient temperature gas zone 0 T5 -25 ... 75 °C
Ambient temperature gas zone 0 T4 -25 ... 75 °C
Ambient temperature gas zone 0 T3 -25 ... 75 °C
Maximum values Ui = 9.6 V / li = 50.5 mA / Pi = 121.3 mW / Ci = 3.54 nF / Li = 1.3 µH
Compressive strength (at 25°C) 16 bar
Material sensor touched by medium stainless steel AISI 316 Ti, glass
Material housing stainless steel AISI 316 Ti
Seal material FFKM (Kalrez)
Sensitivity constant for all detectable media
Protection [EN 60529] IP 67
Electrical connection 2 m PVC-cable 3x0.5 mm²
Associated amplifiers IKMb 123 Ex...